| High performance AC drive |
Smooth operation, precise control and powerful functionality
EI-Super N is a general-purpose inverter with flux vector control. It directly controls the current or torque in an AC induction motor. EI-Super N is suitable for a wide variety of applications.
EI-Super N provides smooth start-up at low speeds (1% of rated speed) and precise operation. Its auto-tuning function enables high performance tuning of all induction motors.
EI-Super N features full-scale flux vector current control that directly controls motor torque based on present control theory utilising a magnetic flux observer and neuro-control.
It features full torque control even at zero speed when PG option is added.
Precise control over a wide speed range |
 |
Features:
- 32bit DSP microprocessor configuration
- magnetic field oriented flux vector control
- auto-tune ability
- available for speed-type servo controller while PG feedback added
- RS-232/RS-485 serial communication port
- RS232/TCP-IP interface card
- capacities from 1HP - 400 HP
- optional DC reactor available (for reducing harmonic interference from the power supply)
- multi-language large screen LCD displays the drive status in six languages and a parameter copy mode function.
(English, Chinese, Russian, German, French & Spanish).
|
| Any type of machine starts smoothly at low speeds |
| EL - MINI SERIES-1500w |
| 110v 200w-750w / 220v 200w - 1500w / 440v 750w-1500w |
 |
Features:
- Solid state reversing
- 2 - wire or 3 wire control inputs
- Digital output for Drive Healthy
- Constant totque or variable torque V / HZ Patterns
- 100 / 120 hz maxamun frequency
- + 15 Vdc power spply for external devices
- External inputs for drive enable and fault reset
- Electronic motor overload protections
for more informationand specifications
- contact sales on:01527-520782
|
Pure Sine Wave Inverter with UPS Power Backup
Ups mode Plus 12/24/48V-600-3000W
|
| Remote control unit for power output ON-OFF and power save mode, reset, error message.-etc by RS485. Switch selectable 50 or 60Hz output, all models. Tightly regulated output voltage and frequency. Thermostatically controlled cooling fan. Built-in battery voltage and output watts scale meter. Bellow 1-Watt consumption in power save mode. |
 |
Features:
- Microprocessor based design with absolutely accurate and stable frequency.
- Very low harmonic distortion, THD <3%.
- Panel indicators for battery voltage & load level (%).
- Compact and lightweight, yet rugged and vehicle rated, 83-86% efficient.
- Capable of driving highly reactive loads such as electric tools and appliances.
- Built-in fast acting AC synchornised transfer switch (<10msec).
|
| CombiPlus 12/24/48V-1500-6000W |
- Combi-functional, with intelligent shore and generator power management
Uninterrupted AC power (UPS function) Virtually unlimited power thanks to parallel operationThree phase capability , powerControl — Dealing with limited generator, shore side or grid power to avoid sudden loads on generator causing voltage spikes , PowerSupport — Boosting the capacity of shore or generator power, an innovative feature of the CombiPlus
|

|
Features:
- Four stage adaptive charger and dual battery charging
- LCD display for parameter setting and error messages
- Programming auxiliary relay ( X 3)
- Programming input current limit for power share
- Communication with max. 10 sets of solar chargers (SunStar Series)
- Four preset control mode application with AC grid, AC charging and solar charging
- Wall Mount and Table Mount available for choices
- Optional remote panel with LCD display for easy operation in distance
|
Universal Battery Charger 2/3/4/8 Stage Intelligent
12V-60, 120 Amp
24V-35, 70 Amp
48V-18, 35 Amp
|
| Microprocessor controlled power management Auto ranging for power supply from 90265 VAC and both 50/60Hz Built-in active PFC function PF>0.95 Full charge current with full output voltage and negligible reduction at high ambient temperature |
 |
Features:
- Built-in temperature compensation function for safe and complete charging
- 2/3/4/8 stage smart process guarantee fast and complete charging for lead-acid batteries
- Clear LCD display on the front with accurate read-out of batteries information, charging patterns and parameter settings
- Built-in two or three battery outlets and two or three programmable auxiliary relays
- Supports Flood Lead Acid (FLA), GEL and AGM batteries
- Remote panel available as option and built-in remote on-off control terminal
|
EI-450MINI Series - Power Saving Inverter
220V Class (1-Phase Input) 200W~2HP
220V Class (3-Phase Input) 200W~2HP
440V Class (3-Phase Input) 400W~2HP |
Complete Protective Functions
-
High-speed current limit to prevent over current (200% or more of the rated current), tripless operation (Momentary power loss restart, stall prevention, fault reset)
-
Built-in rush current limited circuit
-
Ground fault protection
|
 |
Features:
- Full-range automatic torque boost
- slip compensation
- 9-step speed operation (Max.)
- momentary power loss at restart
- frequency reference bias/gain
- fault reset
- speed search
- reference upper /lower limit setting
- overtorque detection
- frequency hold command
- DC injection braking current/ time at start/ stop frequency
- accel/decel time select
- accel/decel hold command
- accel/decel S pattern
- frequency reference with built-in potentiometer
- frequency reference setting
- constants copy (accessory option)
|
High Efficiency Grid Tie Inverter for Renewable Power
Grid Tie Inverter 12/24/48V-1000W
|
AC and DC circuit breakers included Can be operated and connected to batteries.
|
 |
Features:
- Suitable for user with solar modules, wind generators, Micro Hydro and other renewable sources
- Maximum power point tracking system (MPPT)
- Galvanically isolated
- High efficiency toroidal transformer
- Pure sine wave power output and low total harmonic distortion
- Clear LCD display on the front with accurate read-out information and parameters setting and operation messages
- Communication with Combi-3/CombiPlus/SuperCombi without limitation of power
|
Auto Transfer Switch
Amp, ATS-40:40 Amp
|
| Auto Transfer Switch with 2 AC Input Bypass for Loads |
 |
Features:
- Power bypass to secure power source
- Suitable for video recorders, computers, microwave ovens, etc.
- Two AC INPUTS to supply to AC loads
- Master input and Slave input
- Input source can be generators, inverters, mains, etc.
- Total switching time less than 12 msec
- Switching capacity: 20Amps, 40Amps
- Frequency: 50/60Hz (selectable)
- Universal output sockets to be plugged in
- Easy understanding LED indicators to display the power condition
|
Powerful Pure Sine Wave Inverter to Convert Battery Power to Supply AC Loads
Low Frequency 12/24/48V-150-6000W
|
These pure sine wave inverters are specially designed to fulfil the needs of special applications where it is necessary to adapt several parameters of inverters .State-of -Art auto load sense. Standard inbuilt low battery cut-off. Great overload performance.
|
 |
Features:
- Very efficient stand by circuit.
- Do not effect other equipment like TV, radio, etc.
- No problem with microwave ovens.
- Extremely efficient.
- Standard specially designed AC- and DC - line filters.
- Can be used anywhere including National Parks.
- Aluminum chassis for harsh environments.
- Built-in Remote Controller Port.
- Compact.
- Simplified system design.
- Easily mounted.
- Lowest installation cost.
|
DOL starters and overloads 1PH & 3PH
NQ3-5.5KW IP55 Rated Direct On Line Starter
NQ3-11P-11KW IP55 Rated Direct On Line Starter |
 |
NQ3-5.5P/110V- 5.5KW 110V COIL
NQ3-5.5P230V -5.5KW 230V COIL
NQ3-5.5P/415V-5.5KW 415V COIL
NQ3-3-11P/110V-11KW 110V COIL
NQ3-3-11P/230V-11KW 230V COIL
NQ3-3-11P/230V-11KW 230V COIL |
| NR2 Overload Relays For Use With NC1 Contactors & NQ3 Direct On Line Starters. |
 |
NR2-0.16 - 0.10A-0.16A
NR2-0.25 - 0.16A-0.25A
NR2-0.40 - 0.25A-0.40A
NR2-0.63 - 0.40A-0.63A
NR2-1.00 - 0.63A-1.00A
NR2-1.60 - 1.00A-1.60A NR2-2.00 - 1.25A-2.00A
NR2-2.50 - 1.60A-2.50A
NR2-4.00 - 2.50A-4.00A
NR2-6.00 - 4.00A-6.00A
NR2-8.00 - 5.50A-8.00A
NR2-10.00 - 7.00A-10.00A NR2-13.00 - 9.00A-13.00A
NR2-18.00 - 12.00A-18.00A
NR2-25.00 - 17.00A-25.00A |